Pfeiffertheface.com

Discover the world with our lifehacks

Can a p-trap be higher than the drain pipe?

Can a p-trap be higher than the drain pipe?

You attach the p-trap directly to the drainage and manuever the p-traps exits into you existing drain. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally.

Can you put a 90 in a sink drain?

It’s fine to have a larger-radius (sweep) 90-degree bend at the base of a vertical drainage stack where the wastewater starts to travel horizontally. It’s also a good idea to have a sweep 90-degree fitting where a drain pipe pops out of a wall for a kitchen, vanity or laundry sink.

What if new sink drain doesn’t line up with existing pipes?

If the tailpiece will not line up with the trap, move the trap into its original position, tighten the collar with the pipe wrench and obtain a flexible tailpiece extension for your drain. The size is typically 1 1/4-inch in the outer diameter of the plastic pipe.

How much lower can ap trap be from the drain?

Maximum Distance However, the Universal Plumbing Code stipulates that the total developed length of all tailpieces, arms and fittings connecting the drain to the p-trap must be 24 inches or less.

How high should sink drain be from floor?

The standard height of a kitchen sink drain from the floor is between 20 and 24 inches. This varies based on the vanity, sink, and trap.

What can I use instead of AP trap?

Recently I discovered the amazing HepvO Waterless Valve. It’s a new solution to this old problem. Using a flexible silicon tube inside that seals out air but allows water to flow in one direction, it performs the same task without using any water and without being large and bulky like a p-trap.

Can drain lines have elbows?

Caution, wide turns. Use wide-radius elbows for drains to keep the flow of water at a consistent speed. Do not use the sharp, 90-degree vent elbow designed for venting above the water line.

Can P trap turn 90 degrees?

6.3 says this would not be allowed: (c) the trap arm does not have a cumulative change in direction of more than 135°. 90+90 = 180°, so that’s too much.

Can a sink drain run horizontal?

Drain piping can be horizontal (1/4” per foot), vertical, or 450- vent piping shall be free of sags and be graded and connected to drip back by gravity to drain pipe it serves.

Can you use flexible pipe for sink drain?

Flexible drain parts can be used to quickly connect offset sink drains. If you have ever been a little short on pipe or had drain trap fittings that were just shy of the necessary length or angle, you’ll appreciate the usefulness of flexible drain parts.

Does p-trap height matter?

If your P-trap is too low, the water in it is more likely to evaporate, allowing sewer gas to flow up the line. UPC code mandates P-trap height must be 6–18 inches above floor level. This height allows for proper functionality and easy repair of the P-trap.

What height do you stub out vanity drain?

The water supply line runs out of the wall into a hole in the back of the vanity, typically placed at a height of 22 to 24 inches from the finish floor. The sink drain is then situated just 4 inches inward from the water supply line.